South Africa · Public hospitals and private hospital groups

Autonomous UV-C disinfection for hospitals in South Africa

Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University

ryberghealthcare.com · November 2026

The Omnia autonomous UV-C disinfection robot
In the news

Quality standards and infection prevention are rising up the agenda

Bizcommunity · Apr 2026
"South Africa's hospitals show 'uneven capability' as regulator warns compliance is not enough"

The Office of Health Standards Compliance has carried out 4,487 inspections over seven years; 39% of public hospitals were rated excellent

Gauteng Department of Health · Jul 2025
"Gauteng Health implements measures to reduce incidences of nosocomial infections"

A provincial IPC committee meets monthly, supported by HAI surveillance, antimicrobial stewardship teams and IPC refresher training

Daily Investor · Nov 2025
"Life Healthcare results"

Private groups keep investing in capacity, including a new 140-bed hospital in Paarl due to open in the 2027 financial year

Regulators and hospital groups are raising the bar. Measurable, repeatable room disinfection helps hospitals show it.

Sources: COHSASA, via Bizcommunity, 24 April 2026; Gauteng Department of Health, 30 July 2025; Daily Investor (2025)

The South African market

A large public system alongside strong private hospital groups

2.1
hospital beds per 1,000 people: 4.8 in the private sector, 1.8 in the public sector
70,917 + 31,312
public and private hospital beds (national count, 2014)
327 + 217
public and private hospitals (same count)
85%
of the population relies on the public health system

Two main routes to purchase: provincial departments of health and their academic, tertiary and regional hospitals, and the private hospital groups such as Netcare, Life Healthcare and Mediclinic, which decide centrally for many sites.

Sources: Business Day, 15 May 2024; S Afr J Surg, Surgical resources in South Africa: public and private sector (HASA data, 2014); The Healthcare Sector in South Africa 2025, via Business Wire

Healthcare-associated infections
9.7%

of 2,672 patients in four public and two private hospitals in Gauteng had an active healthcare-associated infection in the first South African multi-site prevalence survey

7.7%
HAI prevalence at a tertiary hospital in the Northern Cape; patients with an HAI stayed 20.8 days on average, against 9.1 days for other patients
5,258
carbapenem-resistant Enterobacterales bloodstream infections in national surveillance, 2015–2021
79.8%
of those CRE isolates were K. pneumoniae; 93% produced carbapenemase

Sources: Duse A.G., GARP-SA, HCAI surveillance in South Africa (Gauteng pilot study 2005); Nair et al., S Afr Fam Pract 2018;60(5):162-167; Ismail et al., PLoS One 2025;20(7):e0324262 (NICD)

Capacity

Every bed day counts, especially in intensive care

5
ICU beds per 100,000 people in the public sector at best
69.2%
acute occupancy at Life Healthcare (FY2025)
11.7
extra days in hospital for patients with an HAI in the Northern Cape study

Fewer avoidable infections mean shorter stays and beds that are free sooner for the next patient.

Sources: The Star, via Magzter; Life Healthcare, 27 November 2025; Nair et al. 2018

Healthcare worker in protective clothing
National framework

A regulator, accreditation and provincial IPC programmes

OHSC
the Office of Health Standards Compliance inspects public and private facilities against the national Norms and Standards
205 of 215
private acute hospitals completed the OHSC self-assessment
IPCAF
provinces use the WHO Infection Prevention and Control Assessment Framework to measure compliance

Infection prevention teams must show what is done and how. Omnia records the route and estimated dose of every cycle: measurable evidence for the committee, OHSC inspections and accreditation.

Sources: COHSASA, via Bizcommunity (2026); OHSC to Parliament, via TimesLive, 8 October 2025; Gauteng Department of Health (2025)

The challenge

Cleaning teams do essential work, but manual methods have structural limits

50%
of surfaces considered clean after terminal disinfection
25%
of monitored high-touch objects in operating theatres showed evidence of cleaning
0
records of the dose each surface received: compliance is inferred, not measured

Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)

Cleaning trolley with mop
Omnia robot
The solution

Omnia: autonomous, dose-aware UV-C

Drives itself

Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles

360° UV-C

Eight symmetric, height-optimised lamps with channelled, forced airflow

Dose-aware

A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose

Auditable

Every cycle produces a report of the route and the estimated dose delivered

An extra layer on top of cleaning, not a replacement for it.

Omnia® explained

How Omnia® works, in 90 seconds

Explainer video (1:28) with voice-over and optional captions.

Moving vs static

Why moving UV-C beats a static device

Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.

UV-C dose

C. difficile and UV-C: why the dose matters

Explainer video (2:00) with voice-over and optional captions: why UV-C works by dose, what published studies with stationary UV-C devices found for C. difficile spores and at a distance, and how the operator chooses a target dose on Omnia®. The results for stationary devices were not obtained with Omnia®; the efficacy of Omnia® against bacterial spores is still to be tested, as a follow-up to the Leiden University study.

How a cycle works

What a cycle looks like

1

Terminal clean

The cleaning team completes the regular terminal clean; the room is empty

2

Start

Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience

3

Autonomous cycle

About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)

4

Report

A real-time report of every cycle, as documentation for compliance

5

Release

The room is ready for the next patient

Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

Ryberg Omnia UV-C disinfection robot disinfecting an empty hospital patient room after the terminal clean
Data-driven

Every cycle is verifiable

Example of an Omnia disinfection report with dose map and status

Dose map

The UV-C dose achieved at each point in the room

Status

Cycle fully completed, with date, time and location

Data

Target dose, duration and disinfected area

A new light on safety

Safe for patients, staff and the room

Operated from outside the room

Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running

Immediate cut-out

If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately

Safe after the cycle

No chemical residue and no personal protective equipment needed

Nurse monitoring the Ryberg Omnia UV-C disinfection robot through the window from outside an empty hospital patient room Ryberg Omnia UV-C disinfection robot in an empty operating theatre, seen from above, next to the operating table
Independent evidence

Validated by Leiden University, published in Infection Prevention in Practice

>7-log
reduction of E. coli on the Quick setting
>5-log
reduction of P. putida on the Normal setting
7-log
average for spore-forming B. subtilis on the Deep setting
4–7 min
setup by an operator with no prior experience

The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.

Read the publication on ScienceDirect →   ·   Summary on ryberghealthcare.com →

de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured

The cost of doing nothing

What HAIs mean for a hospital with 30,000 admissions a year

2,910
patients with a healthcare-associated infection (9.7%)
14,550
excess bed days
40
beds occupied all year by those extra days alone

Direct costs

  • Longer length of stay
  • Staff time, laboratory, imaging and theatre
  • Higher level of care, such as intensive care

Indirect costs

  • Fewer beds available, delayed care
  • Reputational damage
  • Insurance and legal costs

Not measurable in money

  • More illness and mortality
  • Lower quality of life
  • Extra burden on clinical teams

Sources: Gauteng multi-site prevalence survey (9.7%). Conservative assumption: 5 extra days per infection. We found no recent published national estimate of the cost per infection, so we show the impact in bed days and beds. Example calculation; replace with your hospital's figures.

Business case · per robot per year

Fewer infections and more beds available

2,400
patients in a room disinfected by Omnia
8 rooms × 300 days
233
of them acquire an HAI
9.7%
47
infections originate from the room and its surfaces
20%
14
infections prevented by disinfection with Omnia
30% fewer
70
bed days freed per year
14 × 5 days
Price on request
purchase price per robot, depending on the contract model
14
patients a year without an avoidable infection
3
models: purchase, hybrid or full service

Example calculation. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer transmissions after additional UV-C disinfection). Also: Gauteng multi-site prevalence survey (9.7%); assumption of 5 extra days per infection.

Beyond the saving

What else Omnia brings to your hospital

Patient safety

Every room thoroughly and verifiably disinfected before the next patient

Staff safety

No extra exposure to disinfectants; the robot is operated from outside the room

Fast room turnaround

A patient room is ready within half an hour after the terminal clean, with no sealing or airing

Relief for teams

Environmental services staff do not need to stay with the cycle and keep time for other work

Evidence for audits

Every cycle report supports your infection prevention programme for OHSC Norms and Standards inspections and COHSASA accreditation surveys

Value for each team

What Omnia brings to a hospital in South Africa

Infection prevention and control

A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance

Nursing and environmental services

No operator needed during the cycle, so staff time goes back to patients and bed turnaround

Cluster management and procurement

Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life

Alternatives

Omnia alongside other methods

FeatureManual disinfectionStatic UV-CHydrogen peroxide vapourOmnia
Staff involvementFull, per surfacePlace and move per positionSeal, start, air outStart and collect
Turnaround timeDepends on executionSeveral cycles per roomLong, including airing13–40 min per 53 m²
CoverageDepends on executionShadow behind objectsGood distribution in the roomDrives around objects, to 15 cm
ResidueAgent may remainNoneDecomposes; airing neededNone
RecordSpot checksLimited, per cyclePer cycleRoute and estimated dose per cycle

Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.

Procurement and financing

Three ways to acquire Omnia

MODEL A

Purchase

One-off purchase, with a service agreement for maintenance, lamp replacement and updates

MODEL B

Hybrid

Deposit up front, the rest in fixed instalments, service included

MODEL C

Full service

Fixed price per month, including maintenance, lamp replacement, updates and support

Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.

Technical specifications
RobotOmnia UV-C Gen1
Dimensions (L × W × H)540 × 540 × 1880 mm
Weight125 kg
Operating temperature10–40 °C
Max. threshold2 cm with ramps, 0.8 cm without
Electric mains110–230 V; 50/60 Hz
Power1,550 W
Product lifetime7 years
UV-C lamps
Number of lamps8
Electric power per lamp75 W
UV output per lamp25 W
Lamp lifespan9,000 hours
Closest approach15 cm to obstacles
Min. pathway0.8 m
Next step

See Omnia in your own hospital

We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.

Nikolaj van Veen, CEO

nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html

Request a demonstration