Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"NCDC tasks health facilities on patient safety, workers' protection"
NCDC has established HAI surveillance systems for real-time detection, monitoring and targeted response
"FG unveils 2025 health facility survey, highlights progress, challenges Report"
The 2025 National Health Facility Survey was conducted with the Federal Ministry of Health and the World Bank
"Survey highlights weaknesses in diagnosis, equipment, drugs availability"
74.1% of facilities had hand-washing units and 79.9% had disposable gloves
National surveillance and new data put infection prevention in focus. Measurable room disinfection supports that work.
Sources: The Guardian Nigeria (2025); News Agency of Nigeria, 7 April 2026
Several routes to purchase: federal teaching hospitals and federal medical centres, state ministries of health, and private hospital groups, which play a significant role at the secondary level.
Source: Federal Ministry of Health, national health facility registry, via Oxford Business Group (2023–2024)
point prevalence of healthcare-associated infections in three acute care hospitals in Northern Nigeria (2019)
Sources: Abubakar U., Antimicrob Resist Infect Control 2020;9:63; eClinicalMedicine 2024;71:102571
Every hour of manual work competes with patient care. Automating a repetitive, measurable step frees time for the team.
Source: National Bureau of Statistics, National Health Facility Survey 2025, via News Agency of Nigeria
Infection prevention teams must show what is done and how. Omnia records the route and estimated dose of every cycle: measurable evidence for the committee, audits and accreditation.
Sources: NCDC (2025); Management Sciences for Health, AMR Alert #6 (December 2025); News Agency of Nigeria (2026)
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimised lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.
Explainer video (2:00) with voice-over and optional captions: why UV-C works by dose, what published studies with stationary UV-C devices found for C. difficile spores and at a distance, and how the operator chooses a target dose on Omnia®. The results for stationary devices were not obtained with Omnia®; the efficacy of Omnia® against bacterial spores is still to be tested, as a follow-up to the Leiden University study.
The cleaning team completes the regular terminal clean; the room is empty
Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: Abubakar 2020 (14.3%). Conservative assumption: 5 extra days per infection. We found no recent published national estimate of the cost per infection, so we show the impact in bed days and beds. Example calculation; replace with your hospital's figures.
Example calculation. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer transmissions after additional UV-C disinfection). Also: Abubakar 2020 (14.3%); assumption of 5 extra days per infection.
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or airing
Environmental services staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your infection prevention programme for NCDC infection prevention programmes and accreditation surveys
A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, air out | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including airing | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; airing needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html