Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"Middle East respiratory syndrome coronavirus – Kingdom of Saudi Arabia"
Nine MERS cases in March–April 2025, including a hospital cluster in Riyadh in which six health and care workers were infected by one patient
"An overview of healthcare-associated Candida auris outbreaks in Ministry of Health hospitals"
511 cases across 45 MOH hospitals in 2020–2022, almost all in intensive care, with a crude mortality of 41.5%
MERS-CoV worldwide overview
Two MERS cases, one fatal, reported by Saudi Arabia in 2026; 2,649 cases and 960 deaths worldwide since 2012
WHO stresses that infection prevention and control measures are critical to prevent healthcare-associated spread. Every room that is verifiably disinfected between patients counts.
Sources: WHO Disease Outbreak News, 12 May 2025; Alanazi et al., PLOS ONE 2025;20(1):e0313589; ECDC, MERS-CoV worldwide overview, 29 September 2026
Public hospitals are organised in regional health clusters, and government procurement is largely centralised. A validated, documented room disinfection layer can be evaluated once and rolled out across a cluster.
Sources: General Authority for Statistics (GASTAT), Healthcare Establishments and Workforce Statistics 2023; Alanazi N.M. et al., J Infect Public Health 2025 (citing the MOH Statistical Book 2023)
of inpatients in six Saudi tertiary-care hospitals had a healthcare-associated infection on the survey day (point prevalence survey, 1,666 patients)
Source: Alshamrani M.M. et al. Burden of healthcare-associated infections at six tertiary-care hospitals in Saudi Arabia: a point prevalence survey. Infect Control Hosp Epidemiol 2019;40(3):355-357 (survey day 11 May 2017)
Every hour of manual disinfection competes with patient care. Automating a repeatable task gives that time back to the team.
Sources: GASTAT, Healthcare Establishments and Workforce Statistics 2023; Alanazi et al., PLOS ONE 2025
More than 60% of the bacteria were resistant, including carbapenem-resistant Enterobacteriaceae. The Ministry's own analysis concludes that strict infection control is essential, including environmental cleaning. Omnia adds a per-cycle record of where it went and the estimated dose delivered.
Source: Alanazi N.M. et al. (General Directorate of Infection Prevention and Control, Ministry of Health). Epidemiology of notifiable outbreaks in different hospital units in Saudi Arabia: a national descriptive study. J Infect Public Health 2025;18:102678 (117 MOH and 53 private hospitals, 2023)
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimised lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.
The cleaning team completes the regular terminal clean; the room is empty
Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: Alshamrani et al., ICHE 2019 (6.8%); Mehmood et al., INQUIRY 2021: average cost of SAR 2,556 per patient day on a medical ward at King Fahd Central Hospital, Jazan (2018, average costing). No national Saudi estimate of the cost per infection is available. Assumption: 5 excess bed days per infection, about SAR 12,800. Conservative: case-mix costing gives SAR 4,501 per day. Worked example; replace with your hospital's own figures.
Worked example based on the purchase price, excluding the service package; price on request. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges on weekends, time for maintenance); 5 excess bed days per infection. Sources: Alshamrani et al., ICHE 2019 (6.8%); Mehmood et al., INQUIRY 2021 (SAR 2,556 per patient day, average costing; SAR 4,501 case-mix); Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer acquisitions after additional UV-C disinfection).
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or airing
Environmental services staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your infection prevention programme towards CBAHI and JCI accreditation surveys
A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, air out | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including airing | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; airing needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html