Kingdom of Saudi Arabia · Health clusters, government and private hospitals

Autonomous UV-C disinfection for Saudi hospitals

Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University

ryberghealthcare.com · October 2026

The Omnia autonomous UV-C disinfection robot
In the news

Infection prevention is a frontline priority in the Kingdom

World Health Organization · May 2025
"Middle East respiratory syndrome coronavirus – Kingdom of Saudi Arabia"

Nine MERS cases in March–April 2025, including a hospital cluster in Riyadh in which six health and care workers were infected by one patient

PLOS ONE · Jan 2025
"An overview of healthcare-associated Candida auris outbreaks in Ministry of Health hospitals"

511 cases across 45 MOH hospitals in 2020–2022, almost all in intensive care, with a crude mortality of 41.5%

ECDC · Sep 2026
MERS-CoV worldwide overview

Two MERS cases, one fatal, reported by Saudi Arabia in 2026; 2,649 cases and 960 deaths worldwide since 2012

WHO stresses that infection prevention and control measures are critical to prevent healthcare-associated spread. Every room that is verifiably disinfected between patients counts.

Sources: WHO Disease Outbreak News, 12 May 2025; Alanazi et al., PLOS ONE 2025;20(1):e0313589; ECDC, MERS-CoV worldwide overview, 29 September 2026

The Saudi market

Close to 500 hospitals in a system being transformed under Vision 2030

499
hospitals in the Kingdom (2023)
65,500
beds in MOH (47,300) and private (18,200) hospitals
1.55 m
admissions a year in the 170 larger hospitals (>100 beds) that report outbreaks
213,110
nurses working in the Kingdom (2023)

Public hospitals are organised in regional health clusters, and government procurement is largely centralised. A validated, documented room disinfection layer can be evaluated once and rolled out across a cluster.

Sources: General Authority for Statistics (GASTAT), Healthcare Establishments and Workforce Statistics 2023; Alanazi N.M. et al., J Infect Public Health 2025 (citing the MOH Statistical Book 2023)

Healthcare-associated infections
6.8%

of inpatients in six Saudi tertiary-care hospitals had a healthcare-associated infection on the survey day (point prevalence survey, 1,666 patients)

27%
of these infections were pneumonia, the most common type
20%
were urinary tract infections; 10.5% bloodstream infections
81%
were not associated with a medical device

Source: Alshamrani M.M. et al. Burden of healthcare-associated infections at six tertiary-care hospitals in Saudi Arabia: a point prevalence survey. Infect Control Hosp Epidemiol 2019;40(3):355-357 (survey day 11 May 2017)

Staffing

Staff time is the scarcest resource on the ward

213,110
nurses in the Kingdom in 2023
44%
of them are Saudi nationals: the system still relies heavily on international recruitment
95.5%
of C. auris cases in MOH hospitals were in intensive care, where nursing time is most precious

Every hour of manual disinfection competes with patient care. Automating a repeatable task gives that time back to the team.

Sources: GASTAT, Healthcare Establishments and Workforce Statistics 2023; Alanazi et al., PLOS ONE 2025

Healthcare worker in protective clothing
National outbreak surveillance

1,240 hospital outbreaks were notified to the Ministry of Health in a single year

806
deaths among 2,392 outbreak patients in 2023: one in three
>70%
of outbreaks occurred in intensive care; Candida auris, Klebsiella and Acinetobacter caused three in four
19.2%
of environmental samples from patient rooms and their surroundings were positive

More than 60% of the bacteria were resistant, including carbapenem-resistant Enterobacteriaceae. The Ministry's own analysis concludes that strict infection control is essential, including environmental cleaning. Omnia adds a per-cycle record of where it went and the estimated dose delivered.

Source: Alanazi N.M. et al. (General Directorate of Infection Prevention and Control, Ministry of Health). Epidemiology of notifiable outbreaks in different hospital units in Saudi Arabia: a national descriptive study. J Infect Public Health 2025;18:102678 (117 MOH and 53 private hospitals, 2023)

The challenge

Cleaning teams do essential work, but manual methods have structural limits

50%
of surfaces considered clean after terminal disinfection
25%
of monitored high-touch objects in operating theatres showed evidence of cleaning
0
records of the dose each surface received: compliance is inferred, not measured

Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)

Cleaning trolley with mop
Omnia robot
The solution

Omnia: autonomous, dose-aware UV-C

Drives itself

Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles

360° UV-C

Eight symmetric, height-optimised lamps with channelled, forced airflow

Dose-aware

A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose

Auditable

Every cycle produces a report of the route and the estimated dose delivered

An extra layer on top of cleaning, not a replacement for it.

Omnia® explained

How Omnia® works, in 90 seconds

Explainer video (1:28) with voice-over and optional captions.

Moving vs static

Why moving UV-C beats a static device

Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.

How a cycle works

What a cycle looks like

1

Terminal clean

The cleaning team completes the regular terminal clean; the room is empty

2

Start

Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience

3

Autonomous cycle

About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)

4

Report

A real-time report of every cycle, as documentation for compliance

5

Release

The room is ready for the next patient

Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

Ryberg Omnia UV-C disinfection robot disinfecting an empty hospital patient room after the terminal clean
Data-driven

Every cycle is verifiable

Example of an Omnia disinfection report with dose map and status

Dose map

The UV-C dose achieved at each point in the room

Status

Cycle fully completed, with date, time and location

Data

Target dose, duration and disinfected area

A new light on safety

Safe for patients, staff and the room

Operated from outside the room

Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running

Immediate cut-out

If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately

Safe after the cycle

No chemical residue and no personal protective equipment needed

Nurse monitoring the Ryberg Omnia UV-C disinfection robot through the window from outside an empty hospital patient room Ryberg Omnia UV-C disinfection robot in an empty operating theatre, seen from above, next to the operating table
Independent evidence

Validated by Leiden University, published in Infection Prevention in Practice

>7-log
reduction of E. coli on the Quick setting
>5-log
reduction of P. putida on the Normal setting
7-log
average for spore-forming B. subtilis on the Deep setting
4–7 min
setup by an operator with no prior experience

The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.

Read the publication on ScienceDirect →   ·   Summary on ryberghealthcare.com →

de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured

The cost of doing nothing

What healthcare-associated infections cost a hospital with 30,000 admissions a year

2,040
patients with a healthcare-associated infection (6.8%)
10,200
excess bed days: 28 beds occupied all year
SAR 26 m
a year, at about SAR 12,800 per infection

Direct costs

  • Longer length of stay
  • Staff, laboratory, imaging and theatre time
  • Higher level of care, such as ICU

Indirect costs

  • Lost capacity, longer waits for admission
  • Bed closures during outbreaks
  • Reputational and legal costs

Not expressed in money

  • More illness and deaths
  • Lower quality of life
  • Extra burden on clinical teams

Sources: Alshamrani et al., ICHE 2019 (6.8%); Mehmood et al., INQUIRY 2021: average cost of SAR 2,556 per patient day on a medical ward at King Fahd Central Hospital, Jazan (2018, average costing). No national Saudi estimate of the cost per infection is available. Assumption: 5 excess bed days per infection, about SAR 12,800. Conservative: case-mix costing gives SAR 4,501 per day. Worked example; replace with your hospital's own figures.

Business case · per robot per year

A worked example: payback in about two years on conservative numbers

2,400
patients in a room that Omnia disinfected
8 rooms × 300 days
163
of them acquire a healthcare-associated infection
6.8% (Saudi PPS)
33
infections arise via the room and surfaces
20%
10
infections prevented by disinfection with Omnia
30% fewer
SAR 127,800
saving per year
10 × SAR 12,780
Price on request
purchase price per robot, depending on the procurement model
±2 years
payback period; with case-mix costs (SAR 4,501 per day) about 15 months
50
bed days a year freed for other patients

Worked example based on the purchase price, excluding the service package; price on request. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges on weekends, time for maintenance); 5 excess bed days per infection. Sources: Alshamrani et al., ICHE 2019 (6.8%); Mehmood et al., INQUIRY 2021 (SAR 2,556 per patient day, average costing; SAR 4,501 case-mix); Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer acquisitions after additional UV-C disinfection).

Beyond the saving

What else Omnia brings to your hospital

Patient safety

Every room thoroughly and verifiably disinfected before the next patient

Staff safety

No extra exposure to disinfectants; the robot is operated from outside the room

Fast room turnaround

A patient room is ready within half an hour after the terminal clean, with no sealing or airing

Relief for teams

Environmental services staff do not need to stay with the cycle and keep time for other work

Evidence for audits

Every cycle report supports your infection prevention programme towards CBAHI and JCI accreditation surveys

Value for each team

What Omnia brings to a Saudi hospital

Infection prevention and control

A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance

Nursing and environmental services

No operator needed during the cycle, so staff time goes back to patients and bed turnaround

Cluster management and procurement

Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life

Alternatives

Omnia alongside other methods

FeatureManual disinfectionStatic UV-CHydrogen peroxide vapourOmnia
Staff involvementFull, per surfacePlace and move per positionSeal, start, air outStart and collect
Turnaround timeDepends on executionSeveral cycles per roomLong, including airing13–40 min per 53 m²
CoverageDepends on executionShadow behind objectsGood distribution in the roomDrives around objects, to 15 cm
ResidueAgent may remainNoneDecomposes; airing neededNone
RecordSpot checksLimited, per cyclePer cycleRoute and estimated dose per cycle

Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.

Procurement and financing

Three ways to acquire Omnia

MODEL A

Purchase

One-off purchase, with a service agreement for maintenance, lamp replacement and updates

MODEL B

Hybrid

Deposit up front, the rest in fixed instalments, service included

MODEL C

Full service

Fixed price per month, including maintenance, lamp replacement, updates and support

Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.

Technical specifications
RobotOmnia UV-C Gen1
Dimensions (L × W × H)540 × 540 × 1880 mm
Weight125 kg
Operating temperature10–40 °C
Max. threshold2 cm with ramps, 0.8 cm without
Electric mains110–230 V; 50/60 Hz
Power1,550 W
Product lifetime7 years
UV-C lamps
Number of lamps8
Electric power per lamp75 W
UV output per lamp25 W
Lamp lifespan9,000 hours
Closest approach15 cm to obstacles
Min. pathway0.8 m
Next step

See Omnia in your own hospital

We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.

Nikolaj van Veen, CEO

nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html

Request a demonstration