Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"Emergence of highly resistant Candida auris in the United Arab Emirates"
National surveillance recorded 9 C. auris cases in 2018 and 614 in 2021, in all seven Emirates; most isolates were resistant to fluconazole and amphotericin B
First national multisector HAI surveillance report
In 92 UAE hospitals, rates of central line-associated bloodstream infection and catheter-associated urinary tract infection were above US NHSN benchmarks in 2023
22.8% of Acinetobacter isolates multidrug- and carbapenem-resistant
Across 65 facilities in Dubai and the Northern Emirates; hospitals were the source of more than 90% of these resistant Acinetobacter and P. aeruginosa isolates
The authors of all three studies point to the same priority: strong infection prevention and control. Every room that is verifiably disinfected between patients counts.
Sources: Thomsen et al., Front Public Health 2024;11:1244358; Tannous et al., Antimicrob Resist Infect Control 2026; Aljaede et al., BMC Infect Dis 2026
Government hospitals are run by SEHA (Abu Dhabi), Dubai Health and Emirates Health Services, alongside large private groups. A validated, documented room disinfection layer can be evaluated once and rolled out across a network.
Sources: Tannous et al., Antimicrob Resist Infect Control 2026; Dubai Health Authority statistics, Q1 2023 (Gulf News, 31 May 2023); Alpen Capital, GCC Healthcare Industry report (Arabian Business)
of hospitalised patients in the Middle East have a healthcare-associated infection on any given day (meta-analysis of 14 point-prevalence studies, 2026)
Sources: Al-Mansouri et al., J Hosp Infect 2026 (meta-analysis); Alothman et al., Int J Infect Dis 2020 (Egypt, Saudi Arabia, UAE, Lebanon, Oman, Kuwait, Bahrain); Abdulrazzaq & Chkhis, Infect Dis Now 2024 (first UAE national PPS, 44 hospitals, 3,657 patients, November 2019)
Every hour of manual disinfection competes with patient care. Automating a repeatable task gives that time back to the team.
Sources: The National, 14 May 2023 (SEHA); Dubai Media Office, 23 September 2025 (Dubai Health); Ministry of Health and Prevention, nursing department (2019)
The national report uses CDC/NHSN definitions and calls device-associated infections and multidrug-resistant organisms the priorities for prevention. Omnia adds a per-cycle record of where it went and the estimated dose delivered, documentation that fits regulators' and accreditors' expectations.
Source: Tannous J., Tannous E., Nazar H., Abdulrazzaq N. National surveillance of healthcare-associated infections in the UAE: first multisector report and benchmark analysis (2023). Antimicrob Resist Infect Control 2026 (92 hospitals; 464 isolates from Dubai and the Northern Emirates)
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimised lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.
The cleaning team completes the regular terminal clean; the room is empty
Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: Al-Mansouri et al., J Hosp Infect 2026 (10.2%, Middle East pooled prevalence; no published national UAE figure); AlShamsi et al., Diabetes Ther 2025: average inpatient cost of AED 4,457 per day at Tawam Hospital, Al Ain (2019–2023, including ICU care). Assumption: 5 excess bed days per infection, about AED 22,300. Worked example; replace with your hospital's own figures.
Worked example, excluding antibiotics, diagnostics, outbreak costs and bed closures; price on request. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges on weekends, time for maintenance); 5 excess bed days per infection at AED 4,457 per day. Sources: Al-Mansouri et al., J Hosp Infect 2026 (10.2%); AlShamsi et al., Diabetes Ther 2025 (AED 4,457 per inpatient day); Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer acquisitions after additional UV-C disinfection).
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or airing
Environmental services staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your infection prevention programme for DoH, DHA and MOHAP inspections and JCI accreditation surveys
A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, air out | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including airing | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; airing needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com