Ryberg
India · Government, trust and private hospitals

Autonomous UV-C disinfection for hospitals in India

Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University

ryberghealthcare.com · November 2026

The Omnia autonomous UV-C disinfection robot
In the news

Capacity, affordability and infection prevention are on the national agenda

Medical Dialogues · Jul 2026
"Health Ministry highlights national guidelines to prevent hospital-acquired infections"

The Ministry of Health and Family Welfare has issued National Guidelines for Infection Prevention and Control in Healthcare Facilities

Moneylife · Aug 2026
"Only 0.79 Govt Hospital Beds Per 1,000 People, Private Care 8–15 Times Costlier: Parliamentary Panel Flags Affordability Crisis"

The private sector accounts for more than 60% of inpatient care, according to the parliamentary committee

Business Today · Jul 2026
"Private hospitals to inject Rs 40,000 cr into India's healthcare expansion"

Major private networks plan to add more than 38,000 beds by 2030

New beds, new national guidance and rising expectations: preventing infections helps every bed do more.

Sources: Medical Dialogues, 31 July 2026; Moneylife, 11 August 2026; Business Today, 3 July 2026

The Indian market

A fast-growing private sector alongside public hospitals

1.3
hospital beds per 1,000 people, below the global median
0.79
government hospital beds per 1,000 people
60%+
of inpatient care delivered by the private sector
38,000+
new beds planned by major private networks by 2030

Two main routes to purchase: state and central government hospitals and medical colleges, and private hospital groups that decide centrally for several sites.

Sources: Bajaj Broking, via Business Today (2026); Parliamentary Standing Committee, via Moneylife (2026)

Healthcare-associated infections
77.7%

of K. pneumoniae from central line-associated bloodstream infections was carbapenem-resistant in around 200 ICUs at 54 hospitals of the Indian HAI surveillance network (2017–2024)

87.1%
of A. baumannii from the same infections carbapenem-resistant
8.83
central line-associated bloodstream infections per 1,000 central line-days
13.86
per 1,000 central line-days in neonatal ICUs

Source: Parveen et al., Lancet Glob Health 2025;13(9):e1564-e1573 (Indian HAI surveillance network, AIIMS New Delhi)

In the ICU

An infection in intensive care doubles the cost of treatment

15.3%
of patients in a medical ICU developed an infection during their stay
12.4 → 21.8
days in hospital without and with an ICU-acquired infection
₹87,594
median attributable cost of one ICU-acquired infection

Every infection prevented frees an ICU bed sooner and saves families and hospitals real money.

Source: Chacko et al., World J Crit Care Med 2017;6(1):79-84 (prospective cohort, 499 patients)

Healthcare worker in protective clothing
National framework

National guidance and accreditation that ask for evidence

IPC guidelines
National Guidelines for Infection Prevention and Control in Healthcare Facilities (Ministry of Health and Family Welfare)
NABH
6th edition of the hospital accreditation standards (January 2025) with a dedicated chapter on infection prevention and control
HAI network
standardised HAI surveillance in tertiary hospitals, coordinated by AIIMS New Delhi

Infection control committees must show what is done and how. Omnia records the route and estimated dose of every cycle: measurable evidence for the committee, audits and accreditation.

Sources: Medical Dialogues (2026); NABH Accreditation Standards for Hospitals, 6th edition (2025); Mathur et al., Lancet Glob Health 2022;10(9):e1317-e1325

The challenge

Cleaning teams do essential work, but manual methods have structural limits

50%
of surfaces considered clean after terminal disinfection
25%
of monitored high-touch objects in operating theatres showed evidence of cleaning
0
records of the dose each surface received: compliance is inferred, not measured

Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)

Cleaning trolley with mop
Omnia robot
The solution

Omnia: autonomous, dose-aware UV-C

Drives itself

Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles

360° UV-C

Eight symmetric, height-optimised lamps with channelled, forced airflow

Dose-aware

A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose

Auditable

Every cycle produces a report of the route and the estimated dose delivered

An extra layer on top of cleaning, not a replacement for it.

Omnia® explained

How Omnia® works, in 90 seconds

Explainer video (1:28) with voice-over and optional captions.

Moving vs static

Why moving UV-C beats a static device

Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.

UV-C dose

C. difficile and UV-C: why the dose matters

Explainer video (2:00) with voice-over and optional captions: why UV-C works by dose, what published studies with stationary UV-C devices found for C. difficile spores and at a distance, and how the operator chooses a target dose on Omnia®. The results for stationary devices were not obtained with Omnia®; the efficacy of Omnia® against bacterial spores is still to be tested, as a follow-up to the Leiden University study.

How a cycle works

What a cycle looks like

1

Terminal clean

The cleaning team completes the regular terminal clean; the room is empty

2

Start

Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience

3

Autonomous cycle

About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)

4

Report

A real-time report of every cycle, as documentation for compliance

5

Release

The room is ready for the next patient

Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

Ryberg Omnia UV-C disinfection robot disinfecting an empty hospital patient room after the terminal clean
Data-driven

Every cycle is verifiable

Example of an Omnia disinfection report with dose map and status

Dose map

The UV-C dose achieved at each point in the room

Status

Cycle fully completed, with date, time and location

Data

Target dose, duration and disinfected area

A new light on safety

Safe for patients, staff and the room

Operated from outside the room

Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running

Immediate cut-out

If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately

Safe after the cycle

No chemical residue and no personal protective equipment needed

Nurse monitoring the Ryberg Omnia UV-C disinfection robot through the window from outside an empty hospital patient room Ryberg Omnia UV-C disinfection robot in an empty operating theatre, seen from above, next to the operating table
Independent evidence

Validated by Leiden University, published in Infection Prevention in Practice

>7-log
reduction of E. coli on the Quick setting
>5-log
reduction of P. putida on the Normal setting
7-log
average for spore-forming B. subtilis on the Deep setting
4–7 min
setup by an operator with no prior experience

The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.

Read the publication on ScienceDirect →   ·   Summary on ryberghealthcare.com →

de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured

The cost of doing nothing

What HAIs cost a hospital with 30,000 admissions a year

4,500
patients with a healthcare-associated infection (15%)
22,500
excess bed days: 62 beds occupied all year
₹39.4 crore
a year, at ₹87,594 per infection

Direct costs

  • Longer length of stay
  • Staff time, laboratory, imaging and theatre
  • Higher level of care, such as intensive care

Indirect costs

  • Fewer beds available, delayed care
  • Reputational damage
  • Insurance and legal costs

Not measurable in money

  • More illness and mortality
  • Lower quality of life
  • Extra burden on clinical teams

Sources: WHO 2022 (15 in 100 patients in low- and middle-income countries); conservative assumption of 5 extra days per infection; Chacko et al. 2017 (median attributable cost of an ICU-acquired infection: ₹87,594). Example calculation; replace with your hospital's figures.

Business case · per robot per year

Fewer infections and more beds available

2,400
patients in a room disinfected by Omnia
8 rooms × 300 days
360
of them acquire an HAI
15% (WHO)
72
infections originate from the room and its surfaces
20%
22
infections prevented by disinfection with Omnia
30% fewer
₹19.3 lakh
saving per year
22 × ₹87,594
Price on request
purchase price per robot, depending on the contract model
110
bed days a year freed for other patients
3
models: purchase, hybrid or full service

Example calculation, excluding service package. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer transmissions after additional UV-C disinfection). Also: WHO 2022 (15%); 5 extra days per infection; Chacko et al. 2017 (₹87,594 per infection).

Beyond the saving

What else Omnia brings to your hospital

Patient safety

Every room thoroughly and verifiably disinfected before the next patient

Staff safety

No extra exposure to disinfectants; the robot is operated from outside the room

Fast room turnaround

A patient room is ready within half an hour after the terminal clean, with no sealing or airing

Relief for teams

Environmental services staff do not need to stay with the cycle and keep time for other work

Evidence for audits

Every cycle report supports your infection prevention programme for NABH accreditation and JCI surveys

Value for each team

What Omnia brings to an Indian hospital

Infection prevention and control

A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance

Nursing and environmental services

No operator needed during the cycle, so staff time goes back to patients and bed turnaround

Cluster management and procurement

Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life

Alternatives

Omnia alongside other methods

FeatureManual disinfectionStatic UV-CHydrogen peroxide vapourOmnia
Staff involvementFull, per surfacePlace and move per positionSeal, start, air outStart and collect
Turnaround timeDepends on executionSeveral cycles per roomLong, including airing13–40 min per 53 m²
CoverageDepends on executionShadow behind objectsGood distribution in the roomDrives around objects, to 15 cm
ResidueAgent may remainNoneDecomposes; airing neededNone
RecordSpot checksLimited, per cyclePer cycleRoute and estimated dose per cycle

Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.

Procurement and financing

Three ways to acquire Omnia

MODEL A

Purchase

One-off purchase, with a service agreement for maintenance, lamp replacement and updates

MODEL B

Hybrid

Deposit up front, the rest in fixed instalments, service included

MODEL C

Full service

Fixed price per month, including maintenance, lamp replacement, updates and support

Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.

Technical specifications
RobotOmnia UV-C Gen1
Dimensions (L × W × H)540 × 540 × 1880 mm
Weight125 kg
Operating temperature10–40 °C
Max. threshold2 cm with ramps, 0.8 cm without
Electric mains110–230 V; 50/60 Hz
Power1,550 W
Product lifetime7 years
UV-C lamps
Number of lamps8
Electric power per lamp75 W
UV output per lamp25 W
Lamp lifespan9,000 hours
Closest approach15 cm to obstacles
Min. pathway0.8 m
Next step

See Omnia in your own hospital

We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.

Nikolaj van Veen, CEO

nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html

Request a demonstration
Sources