Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"Healthcare-associated infections and antimicrobial resistance in Canadian hospitals"
Candidozyma (Candida) auris detections in sentinel hospitals rose from 4 in 2020 to 14 in 2024 (colonizations and infections); 90% were fluconazole-resistant
Ontario launches enhanced surveillance of C. auris colonization
From 1 July to 31 December 2026 public health units report colonization cases to the province; hospitals are asked to report new cases voluntarily
"The nursing crunch is easing, but staffing challenges remain in remote areas"
Registered nurse vacancy rates of 13.7% in remote regions, double the rate in accessible regions
Surveillance is tightening while resistant organisms spread: every room that is verifiably disinfected between patients counts.
Sources: Canada Communicable Disease Report 52(5), 29 May 2026; Ontario Associate Chief Medical Officer of Health, memo on C. auris surveillance, 8 June 2026; Statistics Canada, StatsCAN Plus, 12 May 2026
Hospitals are run by provincial health authorities and buy through shared services and group purchasing organizations. A validated, documented room disinfection layer can be evaluated once and rolled out across a region.
Sources: CIHI, Hospital stays in Canada, 2023–2024 (20 February 2025); Canada Communicable Disease Report 52(5), May 2026
of adult patients in Canadian acute care hospitals had at least one healthcare-associated infection on the survey day (national point prevalence survey 2024, 95% CI 7.6–8.6%)
Source: Mitchell R. et al., Infect Control Hosp Epidemiol 2025;46(10):984-991 (CNISP point prevalence surveys 2002–2024)
Every hour of manual disinfection competes with patient care. Automating a repeatable task gives that time back to nursing and environmental services.
Source: Statistics Canada, The nursing crunch is easing, but staffing challenges remain in remote areas (StatsCAN Plus, 12 May 2026)
These organisms can persist on surfaces in patient rooms. Omnia adds a per-cycle record of where it went and the estimated dose delivered, alongside your surveillance and environmental cleaning audits.
Source: Public Health Agency of Canada, Canadian Nosocomial Infection Surveillance Program, Canada Communicable Disease Report 52(5), May 2026
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 operating rooms, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimized lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.
Environmental services completes the regular terminal clean; the room is empty
Position the robot, choose a program and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in operating rooms and ICUs, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: Mitchell et al., ICHE 2025 (8.1%, CNISP hospitals); Leal et al., Infect Control Hosp Epidemiol 2019: attributable cost of hospital-acquired C. difficile infection in Alberta of CAD 18,386 and 5.6 extra days per case (2018 dollars), used here as a proxy for an average infection. Worked example; replace with your hospital's own figures.
Worked example based on the purchase price, excluding the service package; price on request. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Mitchell et al., ICHE 2025 (8.1%, adults in CNISP hospitals, largely larger teaching hospitals); Leal et al., ICHE 2019 (CAD 18,386 and 5.6 days per hospital-acquired C. difficile infection, used as a proxy); Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer acquisitions after additional UV-C disinfection).
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or aeration
Environmental services staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your infection prevention and control program in Accreditation Canada surveys
A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and surveillance
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, aerate | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including aeration | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; aeration needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing available. Through our financing partner you can spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html