Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"Beefed-up infection plan unveiled as Shropshire NHS battles rising C. diff cases"
60 C. difficile cases since April 2026, alongside E. coli, Klebsiella and MRSA; crowded departments and too few isolation rooms named as factors
"Glangwili Hospital closes ward due to rare and 'very contagious' form of scabies outbreak"
Steffan Ward closed to new admissions after an outbreak of crusted scabies among vulnerable patients
"Update to norovirus visiting restrictions"
Visiting restricted to one designated visitor per patient on two wards while a norovirus outbreak was brought under control
Outbreaks, resistant organisms and ward closures affect trusts across the UK every winter and increasingly all year round.
Sources: Shropshire Star, 5 October 2026; ITV News Wales, 10 July 2026; Portsmouth Hospitals University NHS Trust, 11 February 2026
NHS and independent hospitals face the same pressures: rising demand, tight staffing and visible cleanliness standards. The five largest independent operators, including Spire, Circle, Nuffield Health, Ramsay and HCA, hold 75% of private hospital revenue.
Sources: The King's Fund, Key facts and figures (2026); LaingBuisson, Private Healthcare UK Market Report (Oct 2024)
of patients in England had a healthcare-associated infection on the survey day, around one point higher than in 2016 (UKHSA, 2023, 44,372 patients)
Sources: UKHSA point prevalence survey 2023 (121 NHS and independent organisations); Guest et al., BMJ Open 2020 (data 2016/17)
Every hour of manual disinfection competes with patient care. Automating a repeatable task gives that time back to the team.
Sources: NHS England Digital, Sickness Absence Rates (June 2026) and Vacancy Statistics (March 2026)
The standards encourage objective, evidence-based methods. Omnia adds a per-cycle record of where it went and the estimated dose delivered.
Source: NHS England, National Standards of Healthcare Cleanliness 2025
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimised lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating theatre, based on the Leiden University study. Room layouts and dose maps are illustrative.
The cleaning team completes the regular terminal clean; the room is empty
Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: UKHSA point prevalence survey 2023 (7.6%); Guest et al., BMJ Open 2020: 834,000 HCAIs, £2.7 bn and 7.1 million bed days a year in NHS hospitals in England, which gives about £3,240 and 8.5 bed days per infection (2016/17 prices; today's costs are higher). Worked example; replace with your trust's own figures.
Worked example based on the purchase price, excluding the service package. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: UKHSA 2023 (7.6%); Guest et al., BMJ Open 2020 (£3,240 and 8.5 bed days per infection, derived); Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer acquisitions after additional UV-C disinfection). Conservative: 2016/17 prices.
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or airing
Cleaning and estates staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your hygiene policy towards inspection and accreditation
A documented, repeatable disinfection layer per room, alongside your existing cleaning and decontamination protocols
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, air out | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including airing | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; airing needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing available. Through our financing partner you can spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention, nursing and estates teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html