Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University
"Pakistan's health spending below 1% of GDP, reveals Economic Survey 2024–25"
There are currently 1,696 hospitals and 5,434 Basic Health Units operating across the country
"SHCC intensifies province-wide drive to strengthen infection prevention"
The Sindh Healthcare Commission is stepping up its province-wide drive for infection prevention
"Uniforms made mandatory for medics"
The Punjab Healthcare Commission directive for facilities with more than 30 beds is part of efforts to improve infection control
Provincial regulators are raising the bar. Measurable, repeatable room disinfection helps hospitals show progress.
Sources: The Express Tribune, 9 June 2025 and November 2026; Daily Times, 19 July 2026
Several routes to purchase: provincial health departments and teaching hospitals, military hospitals, and private hospital groups and trusts.
Sources: Pakistan Economic Survey 2024-25; State Bank of Pakistan, Annual Report FY25, statistical supplement
of hospitalised patients in 13 hospitals in Punjab had an HAI on the day of the survey; in intensive care it was 33.3%
Sources: Saleem et al., Am J Infect Control 2019;47(4):421-424; Arif et al., Hosp Pract 2021;49(1):34-40; J Ayub Med Coll Abbottabad 2025;37(1):91-6
Every hour of manual disinfection competes with patient care. Automating a repetitive task gives that time back to the team.
Sources: Pakistan Economic Survey 2024-25, via Geo News (10 June 2025); State Bank of Pakistan (FY25)
Infection control committees must show what is done and how. Omnia records the route and estimated dose of every cycle: measurable evidence for the committee, inspections and accreditation.
Sources: National Institute of Health, Pakistan (2020, 2025); Punjab Healthcare Commission, MSDS
Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)
Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles
Eight symmetric, height-optimised lamps with channelled, forced airflow
A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose
Every cycle produces a report of the route and the estimated dose delivered
An extra layer on top of cleaning, not a replacement for it.
Explainer video (1:28) with voice-over and optional captions.
Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.
Explainer video (2:00) with voice-over and optional captions: why UV-C works by dose, what published studies with stationary UV-C devices found for C. difficile spores and at a distance, and how the operator chooses a target dose on Omnia®. The results for stationary devices were not obtained with Omnia®; the efficacy of Omnia® against bacterial spores is still to be tested, as a follow-up to the Leiden University study.
The cleaning team completes the regular terminal clean; the room is empty
Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience
About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)
A real-time report of every cycle, as documentation for compliance
The room is ready for the next patient
Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

The UV-C dose achieved at each point in the room
Cycle fully completed, with date, time and location
Target dose, duration and disinfected area
Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running
If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately
No chemical residue and no personal protective equipment needed


The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.
Read the publication on ScienceDirect → · Summary on ryberghealthcare.com →
de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured
Sources: Saleem et al. 2019 (8.4% in 13 hospitals in Punjab). Conservative assumption: 5 extra days per infection. We found no recent published Pakistani estimate of the cost per infection, so we show the impact in bed days and beds. Example calculation; replace with your hospital's figures.
Example calculation. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer transmissions after additional UV-C disinfection). Also: Saleem et al. 2019 (8.4%); assumption of 5 extra days per infection.
Every room thoroughly and verifiably disinfected before the next patient
No extra exposure to disinfectants; the robot is operated from outside the room
A patient room is ready within half an hour after the terminal clean, with no sealing or airing
Environmental services staff do not need to stay with the cycle and keep time for other work
Every cycle report supports your infection prevention programme for healthcare commission inspections and accreditation
A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance
No operator needed during the cycle, so staff time goes back to patients and bed turnaround
Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life
| Feature | Manual disinfection | Static UV-C | Hydrogen peroxide vapour | Omnia |
|---|---|---|---|---|
| Staff involvement | Full, per surface | Place and move per position | Seal, start, air out | Start and collect |
| Turnaround time | Depends on execution | Several cycles per room | Long, including airing | 13–40 min per 53 m² |
| Coverage | Depends on execution | Shadow behind objects | Good distribution in the room | Drives around objects, to 15 cm |
| Residue | Agent may remain | None | Decomposes; airing needed | None |
| Record | Spot checks | Limited, per cycle | Per cycle | Route and estimated dose per cycle |
Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.
One-off purchase, with a service agreement for maintenance, lamp replacement and updates
Deposit up front, the rest in fixed instalments, service included
Fixed price per month, including maintenance, lamp replacement, updates and support
Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.
| Robot | Omnia UV-C Gen1 |
|---|---|
| Dimensions (L × W × H) | 540 × 540 × 1880 mm |
| Weight | 125 kg |
| Operating temperature | 10–40 °C |
| Max. threshold | 2 cm with ramps, 0.8 cm without |
| Electric mains | 110–230 V; 50/60 Hz |
| Power | 1,550 W |
| Product lifetime | 7 years |
| UV-C lamps | |
|---|---|
| Number of lamps | 8 |
| Electric power per lamp | 75 W |
| UV output per lamp | 25 W |
| Lamp lifespan | 9,000 hours |
| Closest approach | 15 cm to obstacles |
| Min. pathway | 0.8 m |
We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.
Nikolaj van Veen, CEO
nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html