Ryberg
Ghana · Teaching, regional, district and private hospitals

Autonomous UV-C disinfection for hospitals in Ghana

Omnia by Ryberg: dose-aware, auditable and independently validated by Leiden University

ryberghealthcare.com · November 2026

The Omnia autonomous UV-C disinfection robot
In the news

A national strategy to prevent healthcare-associated infections

Ghana News Agency · Feb 2024
"MOH launch National Infection Prevention and Control Strategy"

The five-year strategy (2024–2028) aims to prevent, reduce and control healthcare-associated infections and antimicrobial resistance

Ghana News Agency · Mar 2026
"Ghana operating at 0.7 hospital beds per 1,000 people -GRNMA"

The nurses' and midwives' association warns that emergency care is under severe strain

MyJoyOnline
"Ghana's hospital bed ratio stands at 0.9 per 1000, below WHO standard"

The Korle-Bu board chairman notes that WHO recommends 2 to 5 beds per 1,000 people

With so few beds, every bed day saved counts. Preventing infections helps each bed serve more patients.

Sources: Ghana News Agency, 22 February 2024 and 27 March 2026; MyJoyOnline

The Ghanaian market

Teaching, regional and district hospitals, with a growing private sector

0.7–0.9
hospital beds per 1,000 people
3 + 10
teaching hospitals and regional hospitals, plus about 162 district hospitals
12,806
beds in government hospitals (2017)
16.9%
of hospital beds managed by the private sector (2016)

Several routes to purchase: the Ministry of Health and Ghana Health Service, the teaching hospitals, faith-based hospitals and private hospital groups in Accra and Kumasi.

Sources: GRNMA, via Ghana News Agency (2026); Labi et al., J Hosp Infect 2019; Ghana Health Service, via Oxford Business Group

Healthcare-associated infections
8.2%

of inpatients in 10 acute care government hospitals had a healthcare-associated infection on the day of the national point prevalence survey

32.6%
of those infections were surgical site infections; 19.5% bloodstream infections
3.5–14.4%
range between hospitals, with higher rates in secondary and tertiary care
61%
of all patients surveyed were on antibiotics

Source: Labi et al., Multi-centre point-prevalence survey of hospital-acquired infections in Ghana, J Hosp Infect 2019;101(1):60-68

Staffing

Staff time is the scarcest resource on the ward

2.7
nurses and midwives per 1,000 people (2019)
22
nurses per 10,000 people in 2016, against a WHO benchmark of 40
0.1
physicians per 1,000 people (2019)

Every hour of manual disinfection competes with patient care. Automating a repetitive task gives that time back to the team.

Source: Oxford Business Group (Ghana Health Service and World Bank data)

Healthcare worker in protective clothing
National framework

A national IPC programme built on WHO core components

2024–2028
National Infection Prevention and Control Strategy of the Ministry of Health
WHO
the strategy follows the WHO guidelines on core components of IPC programmes
All sectors
implementation with the private sector and civil society organisations

Infection prevention teams must show what is done and how. Omnia records the route and estimated dose of every cycle: measurable evidence for the committee, audits and accreditation.

Source: Ghana News Agency, 22 February 2024

The challenge

Cleaning teams do essential work, but manual methods have structural limits

50%
of surfaces considered clean after terminal disinfection
25%
of monitored high-touch objects in operating theatres showed evidence of cleaning
0
records of the dose each surface received: compliance is inferred, not measured

Sources: Demeersseman et al., J Hosp Infect 2023; Jefferson et al., AORN J 2011 (71 theatres, 6 hospitals)

Cleaning trolley with mop
Omnia robot
The solution

Omnia: autonomous, dose-aware UV-C

Drives itself

Plans a full-coverage route, works in 0.8 m pathways and gets within 15 cm of obstacles

360° UV-C

Eight symmetric, height-optimised lamps with channelled, forced airflow

Dose-aware

A cycle ends only when over 85% of waypoints are visited and over 90% received the target dose

Auditable

Every cycle produces a report of the route and the estimated dose delivered

An extra layer on top of cleaning, not a replacement for it.

Omnia® explained

How Omnia® works, in 90 seconds

Explainer video (1:28) with voice-over and optional captions.

Moving vs static

Why moving UV-C beats a static device

Explainer video (1:40) with voice-over and optional captions: moving versus static UV-C in a patient room and an operating room, based on the Leiden University study. Room layouts and dose maps are illustrative.

UV-C dose

C. difficile and UV-C: why the dose matters

Explainer video (2:00) with voice-over and optional captions: why UV-C works by dose, what published studies with stationary UV-C devices found for C. difficile spores and at a distance, and how the operator chooses a target dose on Omnia®. The results for stationary devices were not obtained with Omnia®; the efficacy of Omnia® against bacterial spores is still to be tested, as a follow-up to the Leiden University study.

How a cycle works

What a cycle looks like

1

Terminal clean

The cleaning team completes the regular terminal clean; the room is empty

2

Start

Position the robot, choose a programme and start: 4 to 7 minutes, even without prior experience

3

Autonomous cycle

About 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep)

4

Report

A real-time report of every cycle, as documentation for compliance

5

Release

The room is ready for the next patient

Nobody needs to stay with the robot during the cycle. Ideal after discharge from isolation rooms, in theatres and ICU, and during outbreaks.

Ryberg Omnia UV-C disinfection robot disinfecting an empty hospital patient room after the terminal clean
Data-driven

Every cycle is verifiable

Example of an Omnia disinfection report with dose map and status

Dose map

The UV-C dose achieved at each point in the room

Status

Cycle fully completed, with date, time and location

Data

Target dose, duration and disinfected area

A new light on safety

Safe for patients, staff and the room

Operated from outside the room

Start and monitor from a tablet at the door guard; visual alarms show that a cycle is running

Immediate cut-out

If the connection (heartbeat) between tablet and robot is lost, the lamps switch off immediately

Safe after the cycle

No chemical residue and no personal protective equipment needed

Nurse monitoring the Ryberg Omnia UV-C disinfection robot through the window from outside an empty hospital patient room Ryberg Omnia UV-C disinfection robot in an empty operating theatre, seen from above, next to the operating table
Independent evidence

Validated by Leiden University, published in Infection Prevention in Practice

>7-log
reduction of E. coli on the Quick setting
>5-log
reduction of P. putida on the Normal setting
7-log
average for spore-forming B. subtilis on the Deep setting
4–7 min
setup by an operator with no prior experience

The paper also reports a separate static test under BS 8628:2022, and explains why a static, single-surface protocol does not capture what a moving robot does. We share both results.

Read the publication on ScienceDirect →   ·   Summary on ryberghealthcare.com →

de Jager, Delzenne & Claessen (2026), Infection Prevention in Practice, doi:10.1016/j.infpip.2026.100582 · Laboratory study with model organisms; no clinical endpoints measured

The cost of doing nothing

What HAIs mean for a hospital with 30,000 admissions a year

2,460
patients with a healthcare-associated infection (8.2%)
12,300
excess bed days
34
beds occupied all year by those extra days alone

Direct costs

  • Longer length of stay
  • Staff time, laboratory, imaging and theatre
  • Higher level of care, such as intensive care

Indirect costs

  • Fewer beds available, delayed care
  • Reputational damage
  • Insurance and legal costs

Not measurable in money

  • More illness and mortality
  • Lower quality of life
  • Extra burden on clinical teams

Sources: Labi et al. 2019 (8.2%). Conservative assumption: 5 extra days per infection. We found no recent published national estimate of the cost per infection, so we show the impact in bed days and beds. Example calculation; replace with your hospital's figures.

Business case · per robot per year

Fewer infections and more beds available

2,400
patients in a room disinfected by Omnia
8 rooms × 300 days
197
of them acquire an HAI
8.2%
39
infections originate from the room and its surfaces
20%
12
infections prevented by disinfection with Omnia
30% fewer
60
bed days freed per year
12 × 5 days
Price on request
purchase price per robot, depending on the contract model
12
patients a year without an avoidable infection
3
models: purchase, hybrid or full service

Example calculation. Assumptions: 8 rooms a day (one battery charge: 4 hours of active disinfection, about 27 minutes per room); 300 days a year (fewer discharges at weekends, time for maintenance). Sources: Weinstein (up to 20% via the environment); Anderson et al., Lancet 2017 (30% fewer transmissions after additional UV-C disinfection). Also: Labi et al. 2019 (8.2%); assumption of 5 extra days per infection.

Beyond the saving

What else Omnia brings to your hospital

Patient safety

Every room thoroughly and verifiably disinfected before the next patient

Staff safety

No extra exposure to disinfectants; the robot is operated from outside the room

Fast room turnaround

A patient room is ready within half an hour after the terminal clean, with no sealing or airing

Relief for teams

Environmental services staff do not need to stay with the cycle and keep time for other work

Evidence for audits

Every cycle report supports your infection prevention programme for the National IPC Strategy and accreditation surveys

Value for each team

What Omnia brings to a hospital in Ghana

Infection prevention and control

A documented, repeatable disinfection layer per room, alongside your existing environmental cleaning protocols and IPC surveillance

Nursing and environmental services

No operator needed during the cycle, so staff time goes back to patients and bed turnaround

Cluster management and procurement

Predictable cycles: about 13, 27 or 40 minutes for 53 m² (Quick, Normal, Deep). 110–230 V, 7-year product life

Alternatives

Omnia alongside other methods

FeatureManual disinfectionStatic UV-CHydrogen peroxide vapourOmnia
Staff involvementFull, per surfacePlace and move per positionSeal, start, air outStart and collect
Turnaround timeDepends on executionSeveral cycles per roomLong, including airing13–40 min per 53 m²
CoverageDepends on executionShadow behind objectsGood distribution in the roomDrives around objects, to 15 cm
ResidueAgent may remainNoneDecomposes; airing neededNone
RecordSpot checksLimited, per cyclePer cycleRoute and estimated dose per cycle

Indicative: general characteristics per method. Omnia: own specifications and de Jager et al. (2026). Manual cleaning always remains necessary.

Procurement and financing

Three ways to acquire Omnia

MODEL A

Purchase

One-off purchase, with a service agreement for maintenance, lamp replacement and updates

MODEL B

Hybrid

Deposit up front, the rest in fixed instalments, service included

MODEL C

Full service

Fixed price per month, including maintenance, lamp replacement, updates and support

Financing on request. Spread the investment, so Omnia pays for itself while you pay.
Service and support. A dedicated service portal and first-, second- and third-line support.

Technical specifications
RobotOmnia UV-C Gen1
Dimensions (L × W × H)540 × 540 × 1880 mm
Weight125 kg
Operating temperature10–40 °C
Max. threshold2 cm with ramps, 0.8 cm without
Electric mains110–230 V; 50/60 Hz
Power1,550 W
Product lifetime7 years
UV-C lamps
Number of lamps8
Electric power per lamp75 W
UV output per lamp25 W
Lamp lifespan9,000 hours
Closest approach15 cm to obstacles
Min. pathway0.8 m
Next step

See Omnia in your own hospital

We map your high-touch areas, model cycle times for your rooms and arrange an on-site demonstration with your infection prevention and control, nursing and environmental services teams.

Nikolaj van Veen, CEO

nikolaj.vanveen@ryberghealthcare.com
ryberghealthcare.com/evidence.html

Request a demonstration
Sources