Key benefits of Ryberg Omnia® UV-C over fogging.

Why a modern, autonomous UV-C robot is a realistic alternative to hydrogen peroxide vapour (HPV) fogging for routine terminal disinfection, and what hospitals gain by making the switch.

Ryberg B.V. · White paper · Version 2, October 2026

Key Benefits of Ryberg’s Omnia UV-C Disinfection Robot over Fogging

4 pages · fully referenced · based on peer-reviewed evidence

At a glance

Minutes instead of hours.

Fogging is microbiologically effective, but it takes rooms out of use for hours. Omnia® delivers validated efficacy with a fraction of the downtime.

13–40 min
Omnia® cycle for a room of ~53 m², depending on dose setting, plus 4–7 min set-up¹
~2.5 h
average HPV fogging cycle per patient room (140–177 min)²
>5 log
Omnia® log reduction for all organisms tested, meeting EPA and BS 8628:2022¹

¹ de Jager et al. (2026). ² Havill et al. (2012).

Introduction

Why no-touch disinfection matters.

Healthcare-associated infections (HAIs) remain one of the largest patient-safety challenges in European hospitals. Each year an estimated 4.3 million patients in EU/EEA acute care hospitals acquire at least one HAI, and on average 7.1% of hospitalised patients are affected (ECDC, 2024). HAIs prolong hospital stays, increase costs and contribute to antimicrobial resistance.

Contaminated surfaces play a recognised role in transmission: a patient admitted to a room previously occupied by a patient colonised or infected with certain pathogens has a higher risk of acquiring them. Conventional manual disinfection depends on the operator, which is why hospitals increasingly add “no-touch” automated room disinfection after routine cleaning (Otter et al., 2013; Weber et al., 2016). The two main no-touch technologies are hydrogen peroxide vapour (HPV) fogging and ultraviolet-C (UV-C) light.

The challenge

Practical limitations of fogging.

HPV fogging is microbiologically effective, including against bacterial spores (Havill et al., 2012). Its limitations are mainly practical: time, preparation, safety measures and running costs.

  • Long room downtime. A fogging cycle covers sealing, injecting the vapour, contact time and aeration. In a comparative hospital study, an HPV cycle took on average 153 minutes per patient room (range 140 to 177 minutes), during which the room could not be used (Havill et al., 2012).
  • Room preparation and exposure control. Hydrogen peroxide vapour is hazardous to people. Doors and ventilation openings must be sealed, leakage must be monitored and the room may only be re-entered once the concentration has fallen to a safe level (Otter et al., 2013; Fu et al., 2012).
  • Operator dependency. HPV systems require trained operators and monitoring during the process. In the same study, UV-C was easier to use and could be operated by staff with limited training (Havill et al., 2012).
  • Recurring costs. Every cycle consumes hydrogen peroxide, in addition to equipment maintenance and operator training.

The solution

Ryberg Omnia® UV-C disinfection.

UV-C light inactivates micro-organisms by damaging their DNA and RNA. The added value of UV-C after routine cleaning is supported by clinical evidence: in the multicentre, randomised BETR Disinfection study, adding UV-C to standard terminal cleaning reduced acquisition of the target organisms among subsequent room occupants by 30% (Anderson et al., 2017). Omnia® builds on this evidence with autonomous navigation and dose-controlled disinfection.

Ryberg Omnia® autonomous UV-C disinfection robot with its UV-C lamps switched on in an empty hospital patient room
Omnia® disinfecting an unoccupied patient room after routine cleaning.

Why Omnia® stands out

Eight reasons to make the switch.

Proven efficacy.

In an independent study by the Institute of Biology Leiden, Omnia® achieved log reductions of more than 7 for E. coli, more than 5 for P. putida and more than 7 for B. subtilis, meeting the 5-log criteria of the US EPA and BS 8628:2022 for all organisms tested (de Jager et al., 2026).

Fast and predictable turnaround.

Cycle time follows a simple rule of thumb of about 15 seconds per m² per intensity level. For a room of about 53 m² this is approximately 13 minutes (Quick), 27 minutes (Normal) or 40 minutes (Deep), plus 4 to 7 minutes of set-up (de Jager et al., 2026).

Fewer shadow zones.

UV-C acts in direct line of sight, and areas that are not directly lit receive a lower dose; this is a known limitation of static UV-C devices (Havill et al., 2012). Omnia® moves autonomously through the room with 360° coverage from eight lamps, as close as 15 cm to surfaces. At the same duration, moving disinfection outperformed static UV-C, especially at a partially shadowed location (de Jager et al., 2026).

Dose matched to clinical risk.

Four dose profiles, from Quick for routine turnover to Deep for high-risk and spore-forming pathogens and Custom (40 to 100 mJ/cm²) for outbreak situations.

Documented every cycle.

Each cycle ends with an automatic disinfection report, including a dose heat map of the room and the expected log reduction per pathogen. In the Leiden study, actual results were equal to or better than reported (de Jager et al., 2026).

Chemical-free, room ready immediately.

No chemicals, no residue and no aeration phase. The room can be used again as soon as the cycle has finished.

Safety by design.

Direct exposure to UV-C is harmful to skin and eyes, so Omnia® only operates in unoccupied rooms. Door guards secure the entrances, visual alarms show that a cycle is running and staff start and monitor the robot from a tablet outside the room. No sealing of doors or ventilation is required.

Low operational burden.

No chemical consumables, and a novice operator was ready to start within 4 to 7 minutes (de Jager et al., 2026).

Like fogging, Omnia® is used after routine cleaning. UV-C disinfects surfaces but does not remove dirt, so manual cleaning remains the first step.

Comparative analysis

Omnia® UV-C vs. HPV fogging.

FeatureRyberg Omnia® UV-CHPV fogging
Cycle time per roomapprox. 13 to 40 min for about 53 m², depending on dose setting, plus 4 to 7 min set-up¹approx. 2.5 hours on average (140 to 177 min)²
Room preparationNo sealing of doors or ventilationSealing of doors and ventilation, leak monitoring
Re-entryImmediately after the cycleAfter aeration to a safe concentration
Active agentUV-C light, no chemicalsHydrogen peroxide (consumable)
Exposure risk and controlUV-C is harmful on direct exposure; controlled by operation in unoccupied rooms, door guards and remote controlHazardous vapour; controlled by sealing, monitoring and aeration
Shadowed areasReduced by autonomous movement and 360° coverageVapour distributes through the sealed room
OperationMinimal training; started and monitored remotelyTrained operator required
DocumentationAutomatic dose report with heat map per cycleCycle log; efficacy verified separately
Running costsNo chemical consumablesHydrogen peroxide per cycle, operator training

¹ de Jager et al. (2026). ² Havill et al. (2012), mean HPV cycle time per patient room. Times for other rooms depend on room size and selected dose.

Conclusion

A realistic alternative to fogging.

Fogging is effective, but it takes rooms out of use for hours and requires sealing, aeration, chemicals and trained operators. Ryberg Omnia® offers hospitals a practical alternative for routine terminal disinfection: independently validated efficacy above the 5-log standard, cycles measured in minutes instead of hours, no chemicals, immediate re-entry and a documented dose for every room.

For hospitals that want to strengthen infection prevention while improving room turnover and reducing the operational burden on staff, Omnia® is a well-founded next step. Ryberg is happy to demonstrate Omnia® in your own facility.

Read the summary of the Leiden study →

References

  • Anderson, D. J., Chen, L. F., Weber, D. J., Moehring, R. W., Lewis, S. S., Triplett, P. F., et al. (2017). Enhanced terminal room disinfection and acquisition and infection caused by multidrug-resistant organisms and Clostridium difficile (the Benefits of Enhanced Terminal Room Disinfection study): a cluster-randomised, multicentre, crossover study. The Lancet, 389(10071), 805–814.
  • de Jager, T. R., Delzenne, T. O., & Claessen, D. (2026). Usability and microbial validation study of an autonomous UV-C disinfection robot. Infection Prevention in Practice, 8, 100582. https://doi.org/10.1016/j.infpip.2026.100582
  • European Centre for Disease Prevention and Control (ECDC). (2024). Point prevalence survey of healthcare-associated infections and antimicrobial use in European acute care hospitals, 2022–2023. Stockholm: ECDC.
  • Fu, T. Y., Gent, P., & Kumar, V. (2012). Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems. Journal of Hospital Infection, 80(3), 199–205.
  • Havill, N. L., Moore, B. A., & Boyce, J. M. (2012). Comparison of the microbiological efficacy of hydrogen peroxide vapor and ultraviolet light processes for room decontamination. Infection Control & Hospital Epidemiology, 33(5), 507–512.
  • Otter, J. A., Yezli, S., Perl, T. M., Barbut, F., & French, G. L. (2013). The role of ‘no-touch’ automated room disinfection systems in infection prevention and control. Journal of Hospital Infection, 83(1), 1–13.
  • Weber, D. J., Rutala, W. A., Anderson, D. J., Chen, L. F., Sickbert-Bennett, E. E., & Boyce, J. M. (2016). Effectiveness of ultraviolet devices and hydrogen peroxide systems for terminal room decontamination: focus on clinical trials. American Journal of Infection Control, 44(5 Suppl), e77–e84.

See Omnia® in your own facility.

Compare it with your current fogging routine, room by room.